Cable concentrico
cable concentrico 2 x 4 mm If you don´t find a suitable cable, we will design it for you acc. to your individual requests.
Classification:
Telephone:+86-13523009770
Product Introduction
Application
Conexiones a medidores de energia elQctrica, acometida aerea a medidores y salidas de estos a interruptores de servicios, para evitar el robo de energia electrica.
Construction
Uno, dos, tres o cuatro conductores de cobre electrolitico recocido, suave, solido y cableado (clasel).
Aislamiento termoplastico con cloruro de polivinilo (PVC).
Un neutro compuesto de varios hilos o alambres de cobre aplicados concentricamente sobre el o I os conductores aislados o sobre el relleno.
Cubierta externa de PVC.
Propiedades
Buena resistencia dielectrica, resistencia a la humedad, intemperie, adecuada resistencia a los acidos, grasas y al calor. Retardante a la llama.
Normas de Fabricacion
•NTP-IEC 60502-1
•NTP 370.255-1
•NTP-IEC 60228
・NTP 370.250
Tabla de DatosTecnicos

Cubierta PE
Cinta Poliester
Conductores de Cobre
Aislación PVC
Conductor de Cobre
Alambres Anti-hurto CEC (Concentrico)
|
SECCIÓN mm2 |
DIÁMETRO CONDUCTOR mm |
CONSTRUCCIÓN |
ESPESORES |
DIÁMETRO TOTAL APROXIMA DO mm |
CORRIENTE (AMP) |
PESO APROXIMADO Kg/Km |
||
|
N° HEBRAS |
DIÁMETO DE HEBRAS mm |
AISLACIÓN mm |
CHAQUETA mm |
|||||
|
4 |
2,2 |
32 |
0,4 |
1 |
0,76 |
7,5 |
30 |
105 |
|
6 |
2,73 |
36 |
0,46 |
8 |
45 |
150 |
||
mm2
|
N° COND.X |
DI AM ETRO DE CONDUCTORES |
ESPESORES |
DI AM ETRO PREVISTO |
PESO |
CORRIENTE (*) |
||||
|
CENTRAL |
CONCENTRICO |
AISLAM. |
CUBIERTA |
||||||
|
N° HILOS |
DI AM ETRO |
||||||||
|
N° x mm2 |
N° de Hilos por fase |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
A |
|
|
2x2.5 |
1 |
1.78 |
20 |
0.4 |
1 |
1.8 |
8.2 |
120 |
27 |
|
2x4 |
1 |
2.25 |
32 |
0.4 |
1 |
1.8 |
8.9 |
144 |
37 |
|
4x4 |
1 |
2.25 |
32 |
0.4 |
1 |
1.8 |
15 |
357 |
33 |
|
2x6 |
1 |
2.76 |
48 |
0.4 |
1 |
1.8 |
9.6 |
187 |
48 |
|
2x10 |
1 |
3.57 |
49 |
0.51 |
1 |
1.8 |
10.8 |
273 |
66 |
|
3x4 |
1 |
2.25 |
32 |
0.4 |
1 |
1.8 |
15.4 |
310 |
32 |
|
3x6 |
1 |
2.76 |
48 |
0.4 |
1 |
1.8 |
16.4 |
430 |
43 |
|
3x 10 |
1 |
3.57 |
49 |
0.51 |
1 |
1.8 |
17.8 |
576 |
60 |
|
3x 16 |
7 |
5.1 |
25 |
0.9 |
1 |
1.8 |
21.4 |
867 |
80 |
|
4x6 |
1 |
2.76 |
48 |
0.4 |
1 |
1.8 |
16.1 |
530 |
43 |
|
4x10 |
1 |
3.57 |
49 |
0.51 |
1 |
1.8 |
19.5 |
690 |
60 |
|
4x 16 |
7 |
5.1 |
78 |
0.51 |
1 |
1.8 |
22 |
943 |
80 |
AWG
|
N° DE FASES POR CALIBRE |
DIAMETRO DE CONDUCTORES |
ESPESORES |
DIAMETRO |
PESO |
CORRIENTE |
||||
|
CENTRAL |
CONCENTRICO |
||||||||
|
N° HILOS ] |
DIAMETRO |
AISLAM. |
CUBIERTA |
||||||
|
AWG |
N° Hilos por fase |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
A |
|
|
2x12 |
1 |
2.05 |
26 |
0,404 |
1.0 |
1.8 |
7.5 |
112 |
30 |
|
2x 10 |
1 |
2.59 |
26 |
0z511 |
1.0 |
1.8 |
8.2 |
153 |
42 |
|
2x8 |
1 |
3.26 |
41 |
0,511 |
1.0 |
1.8 |
9.6 |
229 |
55 |
|
3x 12 |
1 |
2.05 |
26 |
0,404 |
1.0 |
1.8 |
14.1 |
314 |
27 |
|
3x10 |
1 |
2.59 |
26 |
0,511 |
1.0 |
1.8 |
15.5 |
370 |
37 |
|
3x8 |
1 |
3.26 |
41 |
0,511 |
1.0 |
1.8 |
19.0 |
545 |
50 |
|
4x6 |
7 |
4.65 |
106 |
0.4 |
1 |
1.8 |
20.8 |
891 |
70 |
600/1000V SINGLE PHASE CONCENTRIC CABLES WITH STRANDED COPPER CONDUCTORS AND COPPER WIRE NEUTRAL CONDUCTORS
|
PHASE CONDUCTOR |
CONCENTRIC NEUTRAL CONDUCTORS NUMBER AND APPROX. DIAMETER OF WIRES |
LAY LENGTHS |
THICKNESS OF OVER- SHEATH |
APPROX. OVERALL DIAMETER OF CABLE |
max. d.c. CONDUCTOR RESISTANCE PER 1 000 m OF CABLE AT 20 0 C |
||||
|
Nominal area |
Number and approximate diameter of wires |
Thickness of insulation |
Phase |
Neutral |
|||||
|
mm2 |
mm |
mm |
mm |
min mm |
max mm |
mm |
mm |
W |
W |
|
4 |
7/0.85 |
1.55 |
24/0.85 |
59 |
118 |
1.4 |
9.75 |
4.61 |
1.343 |
|
6 |
7/1.04 |
1.55 |
26/0.85 |
63 |
127 |
1.4 |
10.72 |
3.08 |
1.240 |
|
10 |
7/1.35 |
1.55 |
29/0.85 |
71 |
142 |
1.4 |
11.73 |
1.83 |
1.151 |
|
16 |
7/1.70 |
1.55 |
26/1.13 |
84 |
167 |
1.4 |
12.78 |
1.15 |
1.007 4 |
|
25 |
7/2.14 |
1.60 |
29/1.13 |
95 |
190 |
1.5 |
14.88 |
0.727 |
0.629 |
|
35 |
19/1.53 |
1.65 |
28/1.35 |
109 |
218 |
1.6 |
16.75 |
0.524 |
0.473 |
600/1000V SINGLE PHASE CONCENTRIC CABLES WITH STRANDED ALUMINIUM CONDUCTORS AND ALUMINIUM WIRE NEUTRAL CONDUCTORS
|
PHASE CONDUCTOR |
CONCENTRIC NEUTRAL CONDUCTORS NUMBER AND APPROX. DIAMETER OF WIRES |
LAY LENGTHS |
THICKNESS OF OVER- SHEATH |
APPROX. OVERALL DIAMETER OF CABLE |
max. d.c. CONDUCTOR RESISTANCE PER 1000 M OF CABLE AT 200 C. |
||||
|
Nominal area |
Number and approximate diameter of wires |
Thickness of insulation |
Phase |
Neutral |
|||||
|
mm2 |
mm |
mm |
mm |
min mm |
max mm |
mm |
mm |
W |
W |
|
10 |
7/1.35 |
1.55 |
23/1.13 |
75 |
151 |
1.4 |
12.21 |
3.08 |
1.335 |
|
16 |
7/1.70 |
1.55 |
26/1.13 |
84 |
167 |
1.4 |
13.34 |
1.91 |
1.808 |
|
25 |
7/2.14 |
1.60 |
29/1.13 |
95 |
190 |
1.5 |
14.88 |
1.20 |
1.058 6 |
|
35 |
19/1.53 |
1.65 |
27/1.35 |
109 |
218 |
1.6 |
16.75 |
0.868 |
1.796 6 |

|
Aluminium Concentric BS 7870 PVC Cable |
Copper LSZH Split Concentric BS7870 |
Aluminium Concentric BS 7870 LSZH Cable |
Aluminium Split Concentric BS 7870 PVC Cable |
Aluminium Split Concentric BS 7870 LSZH Cable |
Copper Concentric BS 7870 PVC Cable |
Copper Split Concentric BS 7870 PVC Cable |
|
| VOLTAGE | 0.6/1kV | ||||||
| CONDUCTOR | Class 1 Solid Aluminium | Class 2 stranded Copper | Class 1 Solid Aluminium | - | - | ||
| INSULATION | XLPE (Cross-Linked Polyethylene) | XLPE (Cross-linked Polyethylene) | XLPE (Cross-Linked Polyethylene) | ||||
| CONCENTRIC CONDUCTOR | Single Layer of Plain Copper Wires | Single Layer of Plain Copper Wires | - | Single Layer of Plain Copper Wires | - | ||
| NEUTRAL CONDUCTOR | - | Plain Copper Wires covered by a Polymeric Compound | - | Plain Copper Wires covered by a Polymeric Compound | - | Plain Copper Wires covered by a Polymeric Compound | |
| EARTH CONTINUITY CONDUCTOR | - | Plain Copper wires | - | Plain Copper Wires | - | Plain Copper Wires | |
| STRING SEPARATOR | - | Non-Hygroscopic | - | Non-Hygroscopic | - | Non-Hygroscopic | |
| OUTER SHEATH | PVC (Polyvinyl Chloride) | LSZH (Low Smoke Zero Halogen) | PVC (Polyvinyl Chloride) | LSZH (Low Smoke Zero Halogen) | PVC (Polyvinyl Chloride) | ||