PVC/XLPE insulated control cable
PVC insulated control cable XLPE Insulated Control Cable If you don´t find a suitable cable, we will design it for you acc. to your individual requests.
Classification:
Telephone:+86-13523009770
Product Introduction
Application
This product is used for electrical appliance and instrument connecting cables in power distribution equipment with AC rated voltage of 450/750V and below.
Its mechanical and physical properties and electrical performance meet the requirements of GB/T9330-2008 "Plastic Insulated Control Cable.
Operating characteristics and electrical performance
1. Cable laying temperature: ≥0°C
2. Long-term allowable operating temperature of cable conductor: 90°C
3. Minimum permissible bending radius:
a. For unarmored cables, should be no less than 6 times of cable outer diameter;
b. For armored or copper belt shield structure cables, should be not less than 12 times of cable outer diameter;
c. For flexible cable with shield structure, shoud be less than six times of cable outer diameter.
4. Finished cable can bear AC 50HZ, 3 KV, 5min withstand test without breakdown.
5. Conductor DC resistance meets the requirements of national standard GB/T3956-2008 “Cable Conductor” and international standard IEC60228.
Cable Models, Names and Laying Occasions
|
Model |
Name |
Laying Occasion |
|
KVV |
Copper core PVC insulated PVC sheathed control cable |
Laid indoors, and in cable trenches, pipelines and other fixed occasions. |
|
KVVP |
Copper core PVC insulated PVC sheathed braid shield control cable |
Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding. |
|
KVVP2 |
Copper core PVC insulated PVC sheathed braid shield control cable |
Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding. |
|
KVV22 |
Copper core PVC insulated PVC sheathed copper belt shield control cable |
Laid indoors, and in cable trenches, pipelines, direct-buring and other fixed places capable of bearing large mechanical force. |
|
KVV32 |
Copper core PVC insulated PVC sheathed steel tape armored control cable |
Laid indoors, and in cable trenches, pipelines, vertical shafts and other fixed places capable of bearing large mechanical force. |
|
KVVR |
Copper core PVC insulated PVC sheathed, fine steel wire armored control cable |
Laid indoors in occasions requiring movement and flexibility. |
|
KVVRP |
Copper core PVC insulated PVC sheathed flexible control cable |
Laid indoors in occasions requiring movement, flexibility and shielding. |
|
KVVP2-22 |
Copper core PVC insulated PVC sheathed copper belt shield steel tape armored control cable |
Laid indoors, and in cable trenches, pipelines and other fixed occasions capable of bearing large mechanical force and requiring shielding. |
Models, Names and Laying Occasions of XLPE Insulated Control Cable
|
Model |
Name |
Laying Occasion |
|
KYJV |
Copper core XLPE insulated PVC sheathed control cable |
Laid indoors, and in cable trenches, pipelines and other fixed occasions. |
|
KYJVP |
Copper core XLPE insulated PVC sheathed braid shield control cable |
Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding. |
|
KYJVP2 |
Copper core XLPE insulated PVC sheathed copper belt shield control cable |
Laid indoors, and in cable trenches, pipelines and other fixed occasions requiring shielding. |
|
KYJV22 |
Copper core XLPE insulated PVC sheathed steel tape armored control cable |
Laid indoors, and in cable trenches, pipelines, direct-buring and other fixed places capable of bearing large mechanical force. |
|
KYJV32 |
KYJV32 Copper core XLPE insulated PVC sheathed fine steel wire armored control cable |
Laid indoors, and in cable trenches, pipelines, vertical shafts and other fixed places capable of bearing large mechanical force. |
|
KYJVR |
Copper core XLPE insulated PVC sheathed flexible control cable |
Laid indoors in occasions requiring movement and flexibility. |
|
KYJVRP |
Copper core XLPE insulated PVC sheathed braid shielding control cable |
Laid indoors in occasions requiring movement, flexibility and shielding. |
|
KYJVP2-22 |
Copper core XLPE insulated PVC sheathed steel tape shielded steel plate armored control cable |
Laid indoors, and in cable trenches, pipelines and other fixed occasions capable of bearing large mechanical force and requiring shielding. |
|
Model |
Rated voltage (V) |
Conductor nominal cross sectional area (mm²) |
|||||||
|
0.75 |
1.0 |
1.5 |
2.5 |
4 |
6 |
10 |
|||
|
KV |
45O/750 |
- |
2-61 |
2-14 |
2-10 |
||||
|
KVVP |
|||||||||
|
KVVP2 |
4-61 |
4-14 |
4-10 |
||||||
|
KVV22 |
- |
7-61 |
4-61 |
4-14 |
4-10 |
||||
|
KVVP2-22 |
|||||||||
|
KVV32 |
- |
19-61 |
7-61 |
4-14 |
4-10 |
||||
|
KVVR |
4-61 |
- |
- |
||||||
|
KVVRP |
4-61 |
4-48 |
- |
- |
|||||
Notes: The recommended number of cores is: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 37, 44, 48, 52 and 61
Range of production
|
Model |
Rated voltage (V) |
Conductor nominal cross sectional area (mm²) |
|||||||
|
0.75 |
1.0 |
1.5 |
2.5 |
4 |
6 |
10 |
|||
|
KYJV |
45O/750 |
- |
2-61 |
2-14 |
2-10 |
||||
|
KYJVP |
|||||||||
|
KYJP2 |
4-61 |
4-14 |
4-10 |
||||||
|
KYJV22 |
- |
7-61 |
4-61 |
4-14 |
4-10 |
||||
|
KYJVP2-22 |
|||||||||
|
KYJV32 |
- |
19-61 |
7-61 |
4-14 |
4-10 |
||||
|
KYJVR |
4-61 |
- |
- |
||||||
|
KYJVRP |
4-61 |
4-48 |
- |
- |
|||||
Notes: The recommended number of cores is: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 37, 44, 48, 52 and 61.
Key words:
PVC/XLPE insulated control cable
Related Products
Product inquiry
Note: Please leave your contact information and our professionals will contact you as soon as possible!