LSZH Instrumentation Cables

CU / XLPE / OS / LSZH ( PAIRS & TRIADS ) CU / XLPE / IS / OS / LSZH ( PAIRS & TRIADS ) CU / XLPE / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) CU / XLPE / IS / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS ) Manufacturer and supplier in China

Telephone:+86-13523009770

Product Introduction

FRT-XOL

CU / XLPE / OS / LSZH ( PAIRS & TRIADS )

XLPE Insulated, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular

Insulation: Cross-linked Polyethylene (XLPE) Compound

Insulation Colour: Pair/s - Black/White with Black numberings Triad/s - Red/Black/White with Black numberings

Cores Twisted: Cores twisted to form a pair, traid or quad

Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core

Wrap Film: Polyester Binder Tape

Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)

Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound

Outer Sheath Colour: Black

ELECTRICAL CHARACTERISTICS

Operating Voltage, Uo/U: 300/500V

Operating Temperature: -15ºC to 90ºC Final Short Circuit Temperature: 250ºC

Test Voltage: 2kV for 1 minute

REFERENCE STANDARDS

Design Specification: BS EN50288-7

Conductor: IEC60228, BS EN60228

Flame Retardancy: IEC60332-3-22, BS EN60332-3-22

Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2

IEC60754-1, IEC60754-2

BS EN50267-2-1, BS EN50267-2-2

FRT-XIOL

CU / XLPE / IS / OS / LSZH ( PAIRS & TRIADS )

XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular

Insulation: Cross-linked Polyethylene (XLPE) Compound

Insulation Colour: Pair/s - Black/White with Black numberings Triad/s - Red/Black/White with Black numberings

Cores Twisted: Cores twisted to form a pair, traid or quad

Wrap Film: Polyester Binder Tape

Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)

Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core

Wrap Film: Polyester Binder Tape

Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)

ELECTRICAL CHARACTERISTICS

Operating Voltage, Uo/U: 300/500V

Operating Temperature: -15ºC to 90ºC Final Short Circuit Temperature: 250ºC

Test Voltage: 2kV for 1 minute

REFERENCE STANDARDS

Design Specification: BS EN50288-7

Conductor: IEC60228, BS EN60228

Flame Retardancy: IEC60332-3-22, BS EN60332-3-22

Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2

IEC60754-1, IEC60754-2

BS EN50267-2-1, BS EN50267-2-2

FRT-XOSL

CU / XLPE / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS )

XLPE Insulated, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular

Insulation: Cross-linked Polyethylene (XLPE) Compound

Insulation Colour: Pair/s - Black/White with Black numberings Triad/s - Red/Black/White with Black numberings

Cores Twisted: Cores twisted to form a pair, traid or quad

Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core

Wrap Film: Polyester Binder Tape

Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)

Bedding: Low Smoke Zero Halogen (LSZH) Compound

Bedding Colour: Black

Armour: Galvanized Steel Wire Armoured (SWA)

Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound

Outer Sheath Colour: Black

ELECTRICAL CHARACTERISTICS

Operating Voltage, Uo/U: 300/500V

Operating Temperature: -15ºC to 90ºC Final Short Circuit Temperature: 250ºC

Test Voltage: 2kV for 1 minute

REFERENCE STANDARDS

Design Specification: BS EN50288-7

Conductor: IEC60228, BS EN60228

Flame Retardancy: IEC60332-3-22, BS EN60332-3-22

Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2

IEC60754-1, IEC60754-2

BS EN50267-2-1, BS EN50267-2-2

FRT-XIOSL

CU / XLPE / IS / OS / LSZH / SWA / LSZH ( PAIRS & TRIADS )

XLPE Insulated, Individual Aluminium Foil Screened, Overall Aluminium Foil Screened, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable, 300 / 500V, BS EN50288-7

CONSTRUCTION

Conductor: Plain Annealed Copper, Class 2 Stranded Circular

Insulation: Cross-linked Polyethylene (XLPE) Compound

Insulation Colour: Pair/s - Black/White with Black numberings Triad/s - Red/Black/White with Black numberings

Cores Twisted: Cores twisted to form a pair, traid or quad

Wrap Film: Polyester Binder Tape

Individual Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (IS)

Lay Up: Multi-pairs, triads or quads are assembled together in concentric layers to form the cable core

Wrap Film: Polyester Binder Tape

Overall Screen: Aluminium/Polyester Tape, with a Tinned Copper Drain Wire 0.5mm2 (7/0.3mm) (OS)

Bedding: Low Smoke Zero Halogen (LSZH) Compound

Bedding Colour: Black

Armour: Galvanized Steel Wire Armoured (SWA)

Outer Sheath: Low Smoke Zero Halogen (LSZH) Compound

Outer Sheath Colour: Black

ELECTRICAL CHARACTERISTICS

Operating Voltage, Uo/U: 300/500V

Operating Temperature: -15ºC to 90ºC

Final Short Circuit Temperature: 250ºC

Test Voltage: 2kV for 1 minute

REFERENCE STANDARDS

Design Specification: BS EN50288-7

Conductor: IEC60228, BS EN60228

Flame Retardancy: IEC60332-3-22, BS EN60332-3-22

Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2

IEC60754-1, IEC60754-2

BS EN50267-2-1, BS EN50267-2-2

CU / XLPE / OS / LSZH ( PAIRS & TRIADS )

SINGLE & MULTI-PAIRS

Key words:

LSZH Instrumentation Cables

Related Products

Product inquiry

Note: Please leave your contact information and our professionals will contact you as soon as possible!