Aerial Bundled Conductor Cable

Aerial Bundled Conductor Cable (ABC) 600/1 000V Medium Voltage ABC cable range: 3.8/6.6kV, 6.35/11kV, 12.7/22kV , 19/33kV Cable Sizes:25mm² 35mm²; 50mm²; 70mm², 95mm² , 120mm², 150mm² and 185 mm² Supplier and Manufacturer in China

Telephone:+86-13523009770

Product Introduction

Low Voltage AERIAL BUNDLED CONDUCTOR - ABC Power Cable

Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system. It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation,maintenance and operative cost. The cables are designed for aerial power lines and room-entrance wires with AC rated voltage 1kV and below.

 

Cable Sizes: 25mm², 35mm², 50mm², 70mm², 95mm², 120mm² and 150mm²

Construction: 1, 2 or 3 Phase cores + Bare Support / neutral Al Alloy + optional 25mm² Street light.

Construction: 1, 2 or 3 Phase cores + Insulated Support / neutral Al Alloy + optional 25mm² Street light

1, 2 or 3 Phase cores + Insulated neutral Aluminium + optional 25mm² Street light.

Medium Voltage ABC cable range: 3.8/6.6kV, 6.35/11kV, 12.7/22kV, 19/33kV:

Conductors: Aluminium Cable

Sizes: Type A : 95 – 185 mm² (3.8/6,6kV, 6.35/11kV, 12.7/22kV, 19/33kV)

Type B : 35 – 185 mm² (3.8/6,6kV, 6.35/11kV, 12.7/22kV)

: 50 – 185 mm² (19/33kV)

Construction: 3 Core, Circular Aluminium Stranded Conductor, XLPE Insulated, Individually Copper tape screened, FR PVC Sheathed + Steel catenary - FR PVC Sheathed

ABC Cable NFC 33-209 Standard

Number of Cores x Nominal Cross Section

Overal Diameter

Weight

Maximum Conductor Resistance

Minimum Breaking Load

Current Rating

No.x mm^2

mm

Kg/Km

Ω/Km

KN

A

2x10 RM

12.8

93

3.08

1.5

38

4x10 RM

15.4

183

3.08

1.5

38

2x16 RM

14.8

129

1.91

2.3

72

2x16 RN + 2x1.5 RE

14.8

176

1.910 / 12.100

2.3

72

4x16 RM

17.8

257

1.91

2.3

72

4x16 RN + 2x1.5 RE

17.8

304

1.910 / 12.100

2.3

72

2x25 RM

18

202

1.2

3.8

107

2x25 RM + 2x1.5 RE

18

249

1.200 / 12.100

3.8

107

4x25 RM

21.7

404

1.2

3.8

107

4x25 RM + 2x1.5 RE

21.7

451

1.200 / 12.100

3.8

107

2x35 RM

20.8

269

0.868

5.2

132

2x35 RM + 2x1.5 RE

20.8

316

0.868 / 12.100

5.2

132

4x35 RM

25.1

539

0.868

5.2

132

4x35 RM + 2x1.5 RE

25.1

586

0.868 / 12.100

5.2

132

2x50 RM

23.4

352

0.641

7.6

165

2x50 RM + 2x1.5 RE

23.4

399

0.641 / 12.100

7.6

165

1x54.6 RM + 3x25 RM

21.7

507

0.630 / 1.200

3.8

107

1x54.6 RM + 3x25 RM + 1x16 RM

24.3

573

0.630 / 1.200 / 1.910

3.8/2.3

107/72

1x54.6 RM + 3x25 RM + 2x16 RM

29.7

639

0.630 / 1.200 / 1.910

3.8/2.3

107/72

1x54.6 RM + 3x25 RM + 3x16 RM

31.1

705

0.630 / 1.200 / 1.910

3.8/2.3

107/72

1x54.6 RM + 3x35 RM

25.1

615

0.630 / 0.868

5.2

132

1x54.6 RM + 3x35 RM + 1x16 RM

28.1

680

0.630 / 0.868 / 1.910

5.2/2.3

132/72

1x54.6 RM + 3x35 RM + 2x16 RM

34.3

748

0.630 / 0.868 / 1.910

5.2/2.3

132/72

1x54.6 RM + 3x35 RM + 3x16 RM

35.9

814

0.630 / 0.868 / 1.910

5.2/2.3

132/72

1x54.6 RM + 3x35 RM + 1x25 RM

28.1

714

0.630 / 0.868 / 1.200

5.2/3.8

132/107

1x54.6 RM + 3x50 RM

28.2

741

0.630 / 0.641

7.6

165

1x54.6 RM + 3x50 RM + 1x16 RM

31.6

806

0.630 / 0.641 / 1.910

7.6/2.3

165/72

1x54.6 RM + 3x50 RM + 2x16 RM

38.6

875

0.630 / 0.641 / 1.910

7.6/2.3

165/72

1x54.6 RM + 3x50 RM + 3x16 RM

40.4

940

0.630 / 0.641 / 1.910

7.6/2.3

165/72

1x54.6 RM + 3x50 RM + 1x25 RM

31.6

841

0.630 / 0.641 / 1.200

7.6/3.8

165/107

1x54.6 RM + 3x70 RM

33

950

0.630 / 0.443

10.2

205

1x54.6 RM + 3x70 RM + 1x16 RM

37

1014

0.630 / 0.443 / 1.910

10.2/2.3

205/72

1x54.6 RM + 3x70 RM + 2x16 RM

45.2

1083

0.630 / 0.443 / 1.910

10.2/2.3

205/72

1x54.6 RM + 3x70 RM + 3x16 RM

47.3

1148

0.630 / 0.443 / 1.910

10.2/2.3

205/72

1x54.6 RM + 3x70 RM + 1x25 RM

37

1048

0.630 / 0.443 / 1.200

10.2/3.8

205/107

1x54.6 RM + 3x70 RM + 2x25 RM

45.2

1150

0.630 / 0.443 / 1.200

10.2/3.8

205/107

1x54.6 RM + 3x70 RM + 3x25 RM

47.3

1250

0.630 / 0.443 / 1.200

10.2/3.8

205/107

1x54.6 RM + 3x95 RM

37.4

1176

0.630 / 0.320

13.5

240

1x54.6 RM + 3x95 RM + 1x16 RM

41.9

1243

0.630 / 0.320 / 1.910

13.5/2.3

240/72

ABC(Aerial Bundle) Cable IEC 60502

Number of cores x 

nominal cross section

min. breaking load of 

conductor strand

Current rating in the air

Outer diameter

Total weight

mm^2

kN

A

mm

kg/km

IEC 60502 & TNB (AL/PE)

1x16+1x 25 RM

6.4

61

15.3

160

3x16+1x 25 RM

6.4

61

19

290

3x25+1x 25 RM

6.4

84

23.2

400

3x35+1x 25 RM

6.4

104

25.6

500

3x50+1x 35 RM

8.9

129

30

680

3x70+1x 50 RM

12.1

167

34.9

920

3x95+1x 70 RM

18

209

40.6

1270

3x120+1x 70 RM

18

246

44.1

1510

3x150+1x 95 RM

24.2

283

49.2

1870

3x185+1x120 RM

30.8

332

54.9

2340

3x25+1x25+1x16 RM

6.4

84

23.2

470

3x35+1x25+1x16 RM

6.4

104

25.6

560

3x50+1x35+1x16 RM

8.9

129

30

740

3x70+1x50+1x16 RM

12.1

167

34.9

980

3x95+1x70+1x16 RM

18

209

40.6

1330

3x120+1x70+1x16 RM

18

246

44.1

1580

3x150+1x95+1x16 RM

24.2

283

49.2

1940

3x185+1x120+1x16 RM

30.8

332

54.9

2410

ABC Cable - DES/LVC IEC 60502 (AL/XLPE)

4x25 RM

3.5

84

21.5

420

4x35 RM

4.9

104

23.9

550

4x120+1x25 RM

16.8

246

43.8

1800

4x185+1x25 RM

25.9

332

50.7

2700

ABC Cable -BS 7870-5 Standard

number of cores x nominal cross section

max. conductor- resistance

min. breaking load of conductor strand

Current rating in the air

Outer diameter

Total weight

mm^2

Ohm/km

kN

A

mm

kg/km

1x 16 RM

1,910

2,5

72

80

74

1x 25 RM

1,200

4,0

107

90

106

1x 35 RM

0,868

5,5

132

105

138

1x 50 RM

0,641

8,0

165

118

182

1x 70 RM

0,443

10,7

205

130

252

1x 95 RM

0,320

13,7

240

154

333

1x 120 RM

0,253

18,6

290

170

408

1x 150 RM

0,206

23,2

334

190

502

1x 185 RM

0,164

28,7

389

210

611

1x 240 RM

0,125

37,2

467

240

801

2x 16 RM

1,910

2,5

72

156

147

2x 25 RM

1,200

4,0

107

180

208

2x 35 RM

0,868

5,5

132

200

277

2x 50 RM

0,641

8,0

165

235

361

2x 70 RM

0,443

10,7

205

254

505

2x 95 RM

0,320

13,7

240

303

666

2x 150 RM

0,206

23,2

334

380

1004

4x 16 RM

1,910

2,5

72

188

286

4x 25 RM

1,200

4,0

107

212

430

4x 35 RM

0,868

5,5

132

241

553

4x 50 RM

0,641

8,0

165

278

746

4x 70 RM

0,443

10,7

205

318

1009

4x 95 RM

0,320

13,7

240

378

1332

4x 120 RM

0,253

18,6

290

544

1632

4x 50 + 1x 25 RM

0,641 / 1,200

8,0 / 4,0

165 / 107

319

814

4x 50 + 1x 35 RM

0,641 / 0,868

8,5 / 5,5

165 /132

319

845

4x 70 + 1x 25 RM

0,443 / 1,200

10,7 / 4,0

205 / 107

360

1105

4x 70 + 2x 25 RM

0,443 / 1,200

10,7 / 4,0

205 / 107

400

1217

4x 95 + 1x 25 RM

0,320 / 1,200

13,7 / 4,0

240 / 107

418

1438

4x 95 + 2x 25 RM

0,320 / 1,200

13,7 / 4,0

240 / 107

420

1544

4x120 + 1x 25 RM

0,253 / 1,200

18,6 / 4,0

290 / 107

590

2050

MV ABC Cable IEC 60502

NUMBER OF CORES X 

NOMINAL CROSS SECTION

PHASE CONDUCTOR

MESSENGER SUSPENSION UNIT

CONTINUOUS CURRENT 

RATING AT 300C 

AMBIENT TEMP

STRANDING

NOMINAL 

SECTIONAL 

AREA

MAXIMUM 

CONDUCTOR 

RESISTANCE

STRANDING

NOMINAL 

SECTIONAL AREA

BREAKING 

LOAD

NO.×MM²

NO.×MM

MM²

Ω/KM

NO.×MM

MM²

KN

A

6.35/11KV

3X50 + 1X25

19/1.78

50

0.641

7/3.0

50

60

116

3X70 + 1X50

19/.14

70

0.443

7/3.15

50

62

210

3X95+ 1X50

19/2.52

95

0.32

7/3.0

50

60

173

3X185+1X120

37/2.52

185

0.164

7/4.67

120

150

259

3X150 +1X50

37/2.25

150

0.206

7/3.15

50

62

365

3X240 +1X50

61/2.25

240

0.125

7/3.15

50

62

500

19/33KV ABC cable

3X50 + 1X50

19/1.78

50

0.641

7/3.0

50

60

165

3X150+ 1X50

37/2.25

150

0.206

7/3.0

50

60

315

3X185+1X70

37/2.52

185

0.164

7/3.57

70

91

355

3X70 +1X50

19/2.14

7

0.443

7/3.15

50

62

250

Key words:

Aerial Bundled Conductor Cable

Related Products

Product inquiry

Note: Please leave your contact information and our professionals will contact you as soon as possible!