ACSR/AW-OC TR/OC Overhead distribution line

ACSR-OC ACSR/AW-OC ACSR/AW-TR/OC Application: Used for weather-resistant cable for the distribution lines on normal condition of overhead line service

Telephone:+86-13523009770

Product Introduction

Overhead distribution line

Overhead distribution line safely transports electricity from substations in suburban areas to its final destination at households, commercial buildings and factories etc. This product is mainly installed on steel towers or concrete electric poles

Aluminum Conductor Steel Reinforced Outdoor Cross-linked Insulated Wire (ACSR-OC)

This product is made by stranding aluminum wire around a zinc coated core steel cable and then applying insulation while extruding it. ACSR-OC is used on high-voltage (6.6kV) and special high-voltage (22.9kV) overhead distribution lines.

Aluminum Conductor Steel Reinforced/Aluminum Clad Outdoor Cross-linked Insulated Wire (ACSR/AW-OC)

This product is made by stranding aluminum wire around a core zinc-coated steel cable and then insulating the wire with cross-linked polyethylene. Corrosion resistance has been improved compared to ACSR. Used on high-voltage (6.6kV) and special high-voltage (22.9kV) overhead distribution lines, this product is suitable for areas subject to slight environmental pollution.

Aluminum Conductor Steel Reinforced/Aluminum Clad Tracking Resistant Outdoor Cross-linked Insulated Wire (ACSR/AW-TR/OC)

This is an improved version of ACSR/AW-OC with double insulation and different insulating materials. Together with improved tracking resistance, less current leakage and better insulation, water-blocking was applied to the conductor to prevent stress breaking and thus improve power supply. Used on special high-voltage (22.9kV) overhead distribution lines, this product is suitable for coastal, industrial and mountainous areas.

22.9kV Aluminum Conductor Aluminum Clad Steel Reinforced Outdoor XLPE Insulated Wire (ACSR/AW-OC)

ES-6145-0006

Nominal
Sectional
Area
Conductor Insulation
Thickness
Overall
Diameter
Max.
Conductor
Resistance
at 20℃
Min.
Insulation
Resistance
at 20℃
Test
Voltage
Min.
Tensile
Load
Approx.
Weight
Standard
Length
Number &
Diameter
of Wire
Number &
Diameter
of Wire
Outer
Diameter
mm2 mm mm mm mm mm Ω/km Ω/km kV kN(kgf) kg/km m
32 6/SB 1/2.6 7.2 3.0 13.2 0.877 2,000 25 10.68(1,090) 210 600, 1000
58 6/SB 1/3.5 9.7 3.0 15.7 0.484 1,500 25 18.62(1,900) 330 600, 1000
95 6/SB 1/3.5 12.0 3.5 19.0 0.302 1,500 25 23.13(2,360) 530 600, 1000
160 18/SB 1/3.2 15.4 4.0 23.4 0.183 1,500 25 30.18(3,080) 730 600, 1000
240 18/SB 1/4.0 18.9 4.0 27.0 0.123 1,000 25 44.10(4,500) 1,040 600, 1000

22.9kV Aluminum Conductor Aluminum Clad Steel Reinforced Outdoor XLPE Insulated Wire (ACSR/AW-TR/OC)

ES-6145-0021

Nominal
Sectional
Area
Conductor Insulation
Thickness
Overall
Diameter
Max.
Conductor
Resistance
at 20℃
Min.
Insulation
Resistance
at 20℃
Test
Voltage
Min.
Tensile
Load
Approx.
Weight
Standard
Length
Number &
Diameter
of Wire
Number &
Diameter
of Wire
Outer
Diameter
mm2 mm mm mm mm mm Ω/km Ω/km kV kN(kgf) kg/km m
58 6/SB 1/3.5 9.7 3.0 15.7 0.484 1,500 25 1,900 360 600
95 6/SB 1/3.5 12.0 3.5 19.0 0.302 1,500 25 2,360 520 600
160 18/SB 1/3.2 15.4 4.0 23.4 0.183 1,500 25 3,080 750 600
240 18/SB 1/4.0 18.9 4.0 27.0 0.123 1,000 25 4,500 1,040 600

ACSR/AW Polyvinyl Chloride Insulated Outdoor Weather-proof wire

(ACSR/AW-OW)

Usage

– An electrically, physically, and chemically outstanding cable made for pad-mounted use from a 22.9kV-y multiple grounding system.

ACSR/AW-OC Structure

– Seal wire : Aluminum-sheathed stranded wire (AW)

– Conductor : Standard aluminum cable

– Interior semi-conductor layer : Black semi-conductor thermosetting compound

– Insulator : weather resistant cross-linked polyethylene (black)

 

ACSR/AW-TR/OC Structure

– Seal wire : Aluminum-sheathed stranded wire (AW)

– Conductor : Standard aluminum cable

– Interior semi-conductor layer : Black semi-conductor thermosetting compound

– Insulator : Weather-resistant cross-linked polyethylene (natural color)

– Sheath : Black semi-conductor thermosetting compound (inner tracking)

GS-6145-0064

Voltage Nominal
Sectional
Area
Conductor Insulation
Thickness
Overall
Diameter
Max.
Conductor
Resistance
at 20℃
Test
Voltage
Min.
Tensile
Load
Approx.
Weight
Standard
Length
Number &
Diameter
of Wire
Number &
Diameter
of Wire
Outer
Diameter
V mm2 mm mm mm mm mm Ω/km kVi kN(kgf) kg/km m
450/750V 35 6/SB 1/2.6 7.2 1.2 9.8 0.868 3 1090 175 900

 

Aluminum Conductor Steel Reinforced Outdoor XLPE Insulated Wire (ACSR/OC)

ES-6145-0008

Voltage Nominal
Sectional
Area
Conductor Insulation
Thickness
Overall
Diameter
Max.
Conductor
Resistance
at 20℃
Min.
Insulation
Resistance
at 20℃
Test
Voltage
Min.
Tensile
Load
Approx.
Weight
Standard
Length
Number &
Diameter
of Wire
Number &
Diameter
of Wire
Outer
Diameter
V mm2 mm mm mm mm mm Ω/km Ω/km kVi kN(kgf) kg/km m
6.6kV 32 6/SB 1/2.6 7.2 2.0 11.2 0.928 1,500 12 1090 185 900
58 6/SB 1/3.5 9.7 2.5 14.7 0.512 1,500 12 1900 325 600
95 6/SB 1/3.5 12.0 2.5 17 0.313 1,000 12 2360 445 300
22.9kV 32 6/SB 1/2.6 7.2 3.0 13.2 0.928 2,000 25 2000 215 900
58 6/SB 1/3.5 9.7 3.0 15.7 0.512 1,500 25 1500 340 600
95 6/SB 1/3.5 12.0 3.5 19 0.313 1,500 25 1500 540 600
160 18/SB 1/3.2 15.4 4,0 23.4 0.186 1,000 25 1500 740 600

Key words:

ACSR/AW-OC TR/OC Overhead distribution line

Related Products

Product inquiry

Note: Please leave your contact information and our professionals will contact you as soon as possible!