0.6/1kV Multiplexed Cables for secondary power distribution

Duplex Triplex Quadruplex Service Drop Wire POLY ACSR POLY Aluminum & POLY All Aluminum Conductors (POLY Al. & POLY AAC PE insulated 75C, 600 Volts Solid sizes AWG #6 to AWG #2. Stranded sizes AWG #6 to 1033.5MCM If you don´t find a suitable cable, we will design it for you acc. to your individual requests.

Telephone:+86-13523009770

Product Introduction

Application

Application: POLY AL. & POLY AAC conductors are primarily used in overhead distribution lines. Installed on insulators, otherwise treated as bare conductor.

Construction: POLY AL & POLY AAC conductors are solid 1350-H19 aluminum and concentrically stranded according to ASTM B 231. Covered with weather resistant black polyethylene compound.

Specification: POLY AL. & POLY AAC meets and exceeds applicable ASTM specifications & ANSI / ICEA-S-70-547 specification.

 

POLY ACSR

PE insulated 75°C, 600 Volts.

Stranded sizes AWG # 6 to 266.8 MCM

Multiplexed cables are suitable for low-voltage electricity supply and distribution circuit of up to 0.6/1kV, as well as for the entire urban and rural secondary network in overhead installations attached to poles or enclosed.

Description for purchase

Multiplexed electrical cable comprised of class 2, soft temper or aluminum alloy 1350 copper wire (number of phase wires and cross-section in “mm2”) with compound insulation (XLPE 90°C thermoset or PE 70°C thermoplastic) and identification by color, letter, number or

frame. Supporting Neutral Wire (bare or insulated) (CAA = Aluminum with steel core, CA = Aluminum, CAL = Aluminum Alloy or CU = Copper). Insulation voltage 0.6/1kV.

Construction

POLY Aluminum & POLY All Aluminum Conductors

Solid sizes AWG#6 to AWG#2. Stranded sizes AWG#6 to 1033.5MCM

Code Name

Size

Stranding

Insul. Thickness

Approx. Over-all Diameter

Rated Strength

Appox. Cable

Weight

Allowable Ampacity

 + (Amps )++

AWG/ MCM

No. / mm

mm

mm

kg

Kg / km

A

Apple

6

4.155

0.76

5.68

201.85

46.77

105

Pear

4

5.189

6.71

321.15

70.38

135

Cherry

2

6.543

1.14

8.83

500.32

116.481

180

Plum

6

7/1.56

0.76

6.20

229.97

51.37

105

Apricot

4

7/1.96

7.40

359.70

77.70

140

Peach

2

7/2.47

1.14

9.70

551.12

128.44

180

Nectarine

1

7/2.78

10.63

669.51

158.22

210

Quince

1/0

7/3.12

1.52

12.41

812.39

207.82

240

Orange

2/0

7/3.50

13.55

1 024.68

254.11

280

Fig

3/0

7/3.93

14.84

1 241.05

312.21

320

Olive

4/0

7/4.42

16.31

1 563.56

385.81

370

 

Pomegranate

4/0

19/268

16.45

1 641.12

381.39

370

Mulberrry

266.8

19/3.01

18.10

2 028.95

471.12

430

Anona

336.4

19/3.38

19.95

2510.67

583.09

495

Mollies

397.5

19/3.67

2.03

22.41

2 902.58

711.60

545

Huckleberry

477.0

37/2.88

24.22

3 547.60

833.20

610

Pawpaw

556.5

37/3.12

25.90

4 075.90

965.02

670

Breadfruit

636.0

61/2.59

2.41

28.14

4 723.33

1 110.61

720

Persimmon

795.0

61/2.90

30.67

5 837.8

1 354.82

825

Grapefruit

1 033.5

61/3.31

34.36

7470.79

1 732.41

970

 

POLY ACSR ALL ALUMINUM CONDUCTORS STEEL REINFORCED

Stranded sizes AWG # 6 to 266.8 MCM

 

Code Name

Size

Stranding No. / mm

Insul. Thick

Approx. Over-all Diameter

Rated Strength

Appox. Cable Weight

Allowable Ampacity + (Amps) ++

AWGZ MCM

Al.

Steel

mm

mm

kg

Kg/km

A

Walnut

6

6 /1.68

1.68

0.76

6.56

513.02

70.37

105

Butternut

4

6/2.12

2.12

7.88

801.51

107.36

135

Hickory

4

7/1.96

2.61

8.01

1 016.97

126.40

135

Pignut

2

6/2.67

2.67

1.14

10.30

1 228.35

175.69

180

Beech

2

7/2.47

3.30

10.53

1 568.55

207.41

180

Chestnut

1

6/3.00

3.00

11.28

1 529.99

215.79

210

Almond

1/0

6/3.37

3.37

1.52

13.16

1 887.43

282.97

235

Pecan

2/0

6/3.78

3.78

14.39

2 288.41

347.03

270

Filbert

3/0

6/4.25

4.25

15.80

2 852.69

429.97

305

Buckeye

4/0

6 /4.77

4.77

17.36

3 598.41

532.19

345

Hackberry

266.8

18/3.09

3.09

18.50

2 964.73

532.34

435

Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

Quadruplex Service Drop Cable

Application

This quadruplexed cable is suited for use as drop cable from a pole mounted transformer to the service entrance of a structure, or as secondary distribution between poles. The cable should be limited to 600V phase to phase and not exceed 90˚C.

CONSTRUCTION

Three insulated phase conductors twisted around a bare aluminum alloy or ACSR neutral conductor.

Conductors: Aluminum alloy 1350-H19 wire.

Insulation: Black thermoset cross-linked polyethylene (XLPE).

Neutral: Bare aluminum alloy or ACSR

ADDITIONAL STANDARDS

ASTM B-230: Aluminum 1350-H19 wire for electrical purposes.

ASTM B-231: Concentric lay stranded aluminum 1350 conductors.

ICEA S-76-474: Neutral supported power cable assemblies with weather resistant extruded insulation rated at 600V.

PRODUCT

PHASE CONDUCTOR 

SIZE

PHASE 

CONDUCTOR STRANDING

BARE NEUTRAL MESSENGER 

SIZE

BARE NEUTRAL MESSENGER 

STRANDING

NEUTRAL TYPE

Clydesdale

4

1

4

7

AAC

Pinto

4

7

4

7

AAC

Mustang

2

7

2

7

AAC

Criollo

1/0

19

1/0

7

AAC

Percheron

2/0

19

2/0

7

AAC

Hanovarian

3/0

19

3/0

19

AAC

Oldenburg

4/0

19

4/0

19

AAC

Bay

6

1

6

7

ACSR

French Coach

6

7

6

7

ACSR

German Coach

4

1

4

7

ACSR

Arabian

4

7

4

7

ACSR

Belgian

2

7

2

7

ACSR

Shetland

1/0

19

1/0

7

ACSR

Thoroughbred

2/0

19

2/0

7

ACSR

Trotter

3/0

19

3/0

7

ACSR

Walking

4/0

19

4/0

7

ACSR

Morochuca

6

1

6

6/1

6201 Alloy

Chola

6

7

6

6/1

6201 Alloy

Morgan

4

1

4

6/1

6201 Alloy

Hackney

4

7

4

6/1

6201 Alloy

Palomino

2

7

2

6/1

6201 Alloy

Costena

1/0

19

1/0

6/1

6201 Alloy

Grullo

2/0

19

2/0

6/1

6201 Alloy

Suffolk

3/0

19

3/0

6/1

6201 Alloy

Appaloosa

4/0

19

4/0

6/1

6201 Alloy

Bronco

336.4

19

336.4

6/1

6201 Alloy

Gelding

336.4

19

4/0

6/1

6201 Alloy

Duplex Service Drop Cable

Application

This duplexed cable is suited for use as drop cable from a pole mounted transformer to the service entrance of a structure, or as secondary distribution between poles. The cable should be limited to 600V phase to phase and not exceed 90˚C.

CONSTRUCTION

One insulated phase conductors twisted around a bare aluminum alloy or ACSR neutral conductor.

Conductors: Aluminum alloy 1350-H19 wire.

Insulation: Black thermoset cross-linked polyethylene (XLPE).

Neutral: Bare aluminum alloy or ACSR

ADDITIONAL STANDARDS

ASTM B-230: Aluminum 1350-H19 wire for electrical purposes.

ASTM B-231: Concentric lay stranded aluminum 1350 conductors.

ICEA S-76-474: Neutral supported power cable assemblies with weather resistant extruded insulation rated at 600V.

ASTM B-232: Concentric lay stranded aluminum conductors coated-steel reinforced

PRODUCT

PHASE CONDUCTOR SIZE

PHASE CONDUCTOR STRANDING

BARE NEUTRAL MESSENGER SIZE

BARE NEUTRAL MESSENGER STRANDING

NEUTRAL TYPE

Pekingese

6

1

6

7

AAC

Collie

6

7

6

7

AAC

Dachshund

4

1

4

7

AAC

Spaniel

4

7

4

7

AAC

Doberman

2

7

2

7

AAC

Malemute

1/0

19

1/0

7

AAC

Setter

6

1

6

6/1

ACSR

Shepherd

6

7

6

6/1

ACSR

Eskimo

4

1

4

6/1

ACSR

Terrier

4

7

4

6/1

ACSR

Chow

2

7

2

6/1

ACSR

Bull

1/0

19

1/0

6/1

ACSR

Chihuahua

6

1

6

7

6201 Alloy

Vizsla

6

7

6

7

6201 Alloy

Harrier

4

1

4

7

6201 Alloy

Whippet

4

7

4

7

6201 Alloy

Schnauzer

2

7

2

7

6201 Alloy

Heeler

1/0

19

1/0

7

6201 Alloy

 

 

Key words:

0.6/1kV Multiplexed Cables for secondary power distribution

Related Products

Product inquiry

Note: Please leave your contact information and our professionals will contact you as soon as possible!