0.6/1KV 1.9/3.3KV PVC Insulated Armored Power Cable
0.6/1KV,1.9/3.3KV, 1-5 Core 2.5-400㎡ Al/Cu Flame Retardant (FR) PVC/PVC AWA/SWA/STA FRLS Power Cable If you don´t find a suitable cable, we will design it for you acc. to your individual requests.
Classification:
Telephone:+86-13523009770
Product Introduction
0.6/1kV Single Core or Multi Cores, Circular Compacted Al or Cu/PVC/PVC armoured or Un-Armoured FRLS Power Cable
|
0.6/1kV PVC Insulated Power Cable |
Conductor |
Insulation |
Armor |
Outer Sheath |
|||||
|
Aluminum |
Copper |
PVC |
SW |
ST |
DST |
AW |
PVC |
PE |
|
|
Cu/PVC/PVC |
P |
P |
--- |
--- |
--- |
--- |
P |
||
|
Cu/PVC/PE |
P |
P |
--- |
--- |
--- |
--- |
P |
||
|
Al/PVC/PVC |
P |
P |
--- |
--- |
--- |
--- |
P |
||
|
Al/PVC/PE |
P |
P |
--- |
--- |
--- |
--- |
P |
||
|
Cu/PVC/STA/PVC |
P |
P |
--- |
P |
--- |
--- |
P |
||
|
Cu/PVC/STA/PE |
P |
P |
--- |
P |
--- |
--- |
P |
||
|
Al/PVC/STA/PVC |
P |
P |
--- |
P |
--- |
--- |
P |
||
|
Al/PVC/STA/PE |
P |
P |
--- |
P |
--- |
--- |
P |
||
|
Cu/PVC/DSTA/PVC |
P |
P |
--- |
--- |
P |
--- |
P |
||
|
Cu/PVC/DSTA/PE |
P |
P |
--- |
--- |
P |
--- |
P |
||
|
Al/PVC/DSTA/PVC |
P |
P |
--- |
--- |
P |
--- |
P |
||
|
Al/PVC/DSTA/PE |
P |
P |
--- |
--- |
P |
--- |
P |
||
|
Cu/PVC/SWA/PVC |
P |
P |
P |
--- |
--- |
--- |
P |
||
|
Cu/PVC/SWA/PE |
P |
P |
P |
--- |
--- |
--- |
P |
||
|
Al/PVC/SWA/PVC |
P |
P |
P |
--- |
--- |
--- |
P |
||
|
Al/PVC/SWA/PE |
P |
P |
P |
--- |
--- |
--- |
P |
||
|
Cu/PVC/AWA/PVC |
P |
P |
--- |
--- |
--- |
P |
P |
||
|
Cu/PVC/AWA/PE |
P |
P |
--- |
--- |
--- |
P |
P |
||
|
Al/PVC/AWA/PVC |
P |
P |
--- |
--- |
--- |
P |
P |
||
|
Al/PVC/AWA/PE |
P |
P |
--- |
--- |
--- |
P |
P |
||
|
Armor material : SW=steel wire, ST=steel tape, DST=double steel tape, AW=aluminum wire |
|||||||||
|
Low Voltage PVC Power Cable |
No. x Nominal Cross Section of Conductor No. x mm² |
|||||||
|
single core |
two cores |
three cores |
3+1 cores |
Four cores |
3+2 cores |
4+1 cores |
5 core |
|
|
0.6/1 kV |
1x4 mm² |
2x4 mm² |
3x4 mm² |
3x4 mm² + 1x2.5mm² |
4x4 mm² |
3x4 mm² + 2x2.5mm² |
4x4 mm² + 1x2.5mm² |
5x2.5 mm² |
|
1x6 mm² |
2x6 mm² |
3x6 mm² |
3x6 mm² + 1x4 mm² |
4x6 mm² |
3x6 mm² + 2x4 mm² |
4x6 mm² + 1x4 mm² |
5x4 mm² |
|
|
1x10 mm² |
2x10 mm² |
3x10 mm² |
3x10 mm² + 1x6 mm² |
4x10 mm² |
3x10 mm² + 2x6 mm² |
4x10 mm² + 1x6 mm² |
5x6 mm² |
|
|
1x16 mm² |
2x16 mm² |
3x16mm² |
3x16 mm² + 1x10 mm² |
4x16 mm² |
3x16 mm² + 2x10 mm² |
4x16 mm² + 1x10 mm² |
5x10 mm² |
|
|
1x 25 mm² |
2x 25 mm² |
3x 25 mm² |
3x25 mm² + 1x16mm² |
4x25 mm² |
3x25 mm² + 2x16mm² |
4x25 mm² + 1x16mm² |
5x16 mm² |
|
|
1x35 mm² |
2x35 mm² |
3x 35 mm² |
3x35 mm² + 1x16mm² |
4x35 mm² |
3x35 mm² + 2x16mm² |
4x35 mm² + 1x16mm² |
5x25 mm² |
|
|
1x50 mm² |
2x50 mm² |
3x 50 mm² |
3x50 mm² + 1x25mm² |
4x50 mm² |
3x50 mm² + 2x25mm² |
4x50 mm² + 1x25mm² |
5x35 mm² |
|
|
1x70 mm² |
2x70 mm² |
3x 70 mm² |
3x70 mm² + 1x35mm² |
4x70 mm² |
3x70 mm² + 2x35mm² |
4x70 mm² + 1x35mm² |
5x50 mm² |
|
|
1x95 mm² |
2x95 mm² |
3x 95 mm² |
3x95 mm² + 1x50mm² |
4x95 mm² |
3x95 mm² + 2x50mm² |
4x95 mm² + 1x50mm² |
5x70 mm² |
|
|
1x120 mm² |
2x120 mm² |
3x 120 mm² |
3x120mm² + 1x70mm² |
4x120 mm² |
3x120mm² + 2x70mm² |
4x120mm² + 1x70mm² |
5x95 mm² |
|
|
1x150 mm² |
2x150 mm² |
3x 150 mm² |
3x150mm² + 1x70mm² |
4x150 mm² |
3x150mm² + 2x70mm² |
4x150mm² + 1x70mm² |
||
|
1x185 mm² |
2x185 mm² |
3x 185 mm² |
3x185mm² + 1x95mm² |
4x185 mm² |
3x185mm² + 2x95mm² |
4x185mm² + 1x95mm² |
||
|
1x240 mm² |
2x240 mm² |
3x 240 mm² |
3x240mm² + 1x120mm² |
4x240 mm² |
3x240mm² + 2x120mm² |
4x240mm² + 1x120mm² |
||
|
1x300 mm² |
3x 300 mm² |
3x300mm² + 1x150mm² |
4x300 mm² |
3x300mm² + 2x150mm² |
4x300mm² + 1x150mm² |
|||
|
1x400 mm² |
||||||||
|
1x500 mm² |
||||||||
|
1x630 mm² |
||||||||
Applications
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. The lead sheath brings an enhanced resistance to aromatic hydrocarbons.
Construction
Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
Insulation
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.
Colour Code
|
1 Core |
Brown or Blue |
|
2 Cores |
Brown, Blue |
|
3 Cores |
Brown, Black, Grey |
|
4 Cores |
Blue, Brown, Black, Grey |
|
5 Cores |
Green/Yellow, Blue, Brown, Black, Grey |
|
Above 5 Cores |
Black Cores with White numerals |
Other colours can be manufactured upon request.
Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
Optional:Lead Sheath
lead or lead alloy and shall be applied as a reasonably tight-fitting seamless tube.Opti
Optional :Seperation Sheath
The seperation sheath shall be of extruded PVC Type ST2 as per IEC 60502-1, or other material refer to outer sheath material.
Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.







|
Type |
Designation |
Main Applications |
|
VV VLV |
Copper(Aluminium)Conducter PVC Insulated and sheathed Power Cable |
For laying indoor and outdoor tunnels, able to bear a centain traction installation, but unable to bear pulling force and pressure, single core cable can not be laid in the magnetic tube. Flame retardant, fire-resistant cable suitable for the places with higher requirements for fire protection. |
|
ZR-VV ZA-VV ZB-VV ZC-VV |
Copper(Aluminium)Conducter Flame Retardant PVC Insulated and sheathed Power Cable |
|
|
NH-VV NHZA-VV NHZB-VV |
Copper(Aluminium)Conducter Fire-resistant PVC Insulated and sheathed Power Cable |
|
|
VV22 VLV22 |
Copper(Aluminium)Conducter PVC Insulated Steel Wire Armoured PVC Sheathed Power Cable |
For laying direct in ground, able to bear a centain traction installation, pulling force and pressure, flame retardant, fire-resistant cable suitable for the place with higher requirements for fire protection. |
|
ZR-VV22 ZA-VV22 ZB-VV22 ZC-VV22 |
Copper(Aluminium)Conducter Flame Retardant PVC Insulated Steel Wire Armoured PVC Sheathed Power Cable |
|
|
NH-VV22 NHZA-VV22 NHZB-VV22 |
Copper(Aluminium)Conducter Fire-resistant PVC Insulated Steel Wire Armoured PVC Sheathed Power Cable |
|
Production Range of Cable: |
|
Type |
No. of Cores |
Nom. Cross-section of Conductor(mm²) |
|
|
Copper Core |
Aluminum Core |
||
|
1 Core |
1.5-630 |
2.5-630 |
|
|
VV VLV ZR-VV ZA-VV ZB-VV ZC-VV ZR-VLV |
2 Cores |
1.5-400 |
2.5-400 |
|
ZA-VLV ZB-VLV ZC-VLV NH-VV NHZA-VV NHZB-VV |
3 Cores |
||
|
NHZC-VV VV22 VLV22 ZR-VV22 ZA-VV22 ZB-VV22 |
4 Cores |
||
|
ZC-VV22 ZR-VLV22 ZA-VLV22 ZB-VLV22 |
5 Cores |
||
|
ZC-VLV22 NH-VV22 NHZA-VV22 NHZB-VV22 |
3+1 Cores |
||
|
NHZC-VV22 |
3+2 Cores |
||
|
4+1 Cores |
|||
Key words:
0.6/1KV 1.9/3.3KV PVC Insulated Armored Power Cable
Related Products
Product inquiry
Note: Please leave your contact information and our professionals will contact you as soon as possible!