0.6/1KV 1.9/3.3KV PVC Insulated Armored Power Cable

0.6/1KV,1.9/3.3KV, 1-5 Core 2.5-400㎡ Al/Cu Flame Retardant (FR) PVC/PVC AWA/SWA/STA FRLS Power Cable If you don´t find a suitable cable, we will design it for you acc. to your individual requests.

Telephone:+86-13523009770

Product Introduction

0.6/1kV Single Core or Multi Cores, Circular Compacted Al or Cu/PVC/PVC armoured or Un-Armoured FRLS Power Cable

0.6/1kV PVC Insulated Power Cable

Conductor

Insulation

Armor

Outer Sheath

Aluminum

Copper

PVC

SW

ST

DST

AW

PVC

PE

Cu/PVC/PVC

 

P

P

---

---

---

---

P

 

Cu/PVC/PE

 

P

P

---

---

---

---

 

P

Al/PVC/PVC

P

 

P

---

---

---

---

P

 

Al/PVC/PE

P

 

P

---

---

---

---

 

P

Cu/PVC/STA/PVC

 

P

P

---

P

---

---

P

 

Cu/PVC/STA/PE

 

P

P

---

P

---

---

 

P

Al/PVC/STA/PVC

P

 

P

---

P

---

---

P

 

Al/PVC/STA/PE

P

 

P

---

P

---

---

 

P

Cu/PVC/DSTA/PVC

 

P

P

---

---

P

---

P

 

Cu/PVC/DSTA/PE

 

P

P

---

---

P

---

 

P

Al/PVC/DSTA/PVC

P

 

P

---

---

P

---

P

 

Al/PVC/DSTA/PE

P

 

P

---

---

P

---

 

P

Cu/PVC/SWA/PVC

 

P

P

P

---

---

---

P

 

Cu/PVC/SWA/PE

 

P

P

P

---

---

---

 

P

Al/PVC/SWA/PVC

P

 

P

P

---

---

---

P

 

Al/PVC/SWA/PE

P

 

P

P

---

---

---

 

P

Cu/PVC/AWA/PVC

 

P

P

---

---

---

P

P

 

Cu/PVC/AWA/PE

 

P

P

---

---

---

P

 

P

Al/PVC/AWA/PVC

P

 

P

---

---

---

P

P

 

Al/PVC/AWA/PE

P

 

P

---

---

---

P

 

P

Armor material :   SW=steel wire, ST=steel tape, DST=double steel tape, AW=aluminum wire

Low Voltage PVC Power Cable
Voltage rating

No. x Nominal Cross Section of Conductor             No. x  mm²

single core

two cores

three cores

3+1 cores

Four cores

3+2 cores

4+1 cores

5 core

0.6/1 kV
 

1x4 mm²

2x4 mm²

3x4 mm²

3x4 mm² + 1x2.5mm²

4x4 mm²

3x4 mm² + 2x2.5mm²

4x4 mm² + 1x2.5mm²

5x2.5 mm²

1x6 mm²

2x6 mm²

3x6 mm²

3x6 mm² + 1x4 mm²

4x6 mm²

3x6 mm² + 2x4 mm²

4x6 mm² + 1x4 mm²

5x4 mm²

1x10 mm²

2x10 mm²

3x10 mm²

3x10 mm² + 1x6 mm²

4x10 mm²

3x10 mm² + 2x6 mm²

4x10 mm² + 1x6 mm²

5x6 mm²

1x16 mm²

2x16 mm²

3x16mm²

3x16 mm² + 1x10 mm²

4x16 mm²

3x16 mm² + 2x10 mm²

4x16 mm² + 1x10 mm²

5x10 mm²

1x 25 mm²

2x 25 mm²

3x 25 mm²

3x25 mm² + 1x16mm²

4x25 mm²

3x25 mm² + 2x16mm²

4x25 mm² + 1x16mm²

5x16 mm²

1x35 mm²

2x35 mm²

3x 35 mm²

3x35 mm² + 1x16mm²

4x35 mm²

3x35 mm² + 2x16mm²

4x35 mm² + 1x16mm²

5x25 mm²

1x50 mm²

2x50 mm²

3x 50 mm²

3x50 mm² + 1x25mm²

4x50 mm²

3x50 mm² + 2x25mm²

4x50 mm² + 1x25mm²

5x35 mm²

1x70 mm²

2x70 mm²

3x 70 mm²

3x70 mm² + 1x35mm²

4x70 mm²

3x70 mm² + 2x35mm²

4x70 mm² + 1x35mm²

5x50 mm²

1x95 mm²

2x95 mm²

3x 95 mm²

3x95 mm² + 1x50mm²

4x95 mm²

3x95 mm² + 2x50mm²

4x95 mm² + 1x50mm²

5x70 mm²

1x120 mm²

2x120 mm²

3x 120 mm²

3x120mm² + 1x70mm²

4x120 mm²

3x120mm² + 2x70mm²

4x120mm² + 1x70mm²

5x95 mm²

1x150 mm²

2x150 mm²

3x 150 mm²

3x150mm² + 1x70mm²

4x150 mm²

3x150mm² + 2x70mm²

4x150mm² + 1x70mm²

 

1x185 mm²

2x185 mm²

3x 185 mm²

3x185mm² + 1x95mm²

4x185 mm²

3x185mm² + 2x95mm²

4x185mm² + 1x95mm²

 

1x240 mm²

2x240 mm²

3x 240 mm²

3x240mm² + 1x120mm²

4x240 mm²

3x240mm² + 2x120mm²

4x240mm² + 1x120mm²

 

1x300 mm²

 

3x 300 mm²

3x300mm² + 1x150mm²

4x300 mm²

3x300mm² + 2x150mm²

4x300mm² + 1x150mm²

 

1x400 mm²

             

1x500 mm²

             

1x630 mm²

             

Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, underground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. The lead sheath brings an enhanced resistance to aromatic hydrocarbons.

Construction

Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.

Insulation

PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.

Colour Code

1 Core

Brown or Blue

2 Cores

Brown, Blue

3 Cores

Brown, Black, Grey

4 Cores

Blue, Brown, Black, Grey

5 Cores

Green/Yellow, Blue, Brown, Black, Grey

Above 5 Cores

Black Cores with White numerals

Other colours can be manufactured upon request.

Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.

Optional:Lead Sheath

lead or lead alloy and shall be applied as a reasonably tight-fitting seamless tube.Opti

Optional :Seperation Sheath

The seperation sheath shall be of extruded PVC Type ST2 as per IEC 60502-1, or other material refer to outer sheath material.

Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.

Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

Four cores(Galvanized steel wire armoured).pngFour cores(Galvanized steel wire armoured) Lead Sheath.png

Single core PVC ( aluminum wire armoured) .png    Three cores(Galvanized steel wire armoured).png

Three cores(Galvanized steel wire armoured) Lead Sheath.pngSingle core( aluminum wire armoured) Lead Sheath.png

Two cores(Galvanized steel wire armoured).pngTwo cores(Galvanized steel wire armoured) Lead Sheath.png

Type

Designation

Main Applications

 VV VLV

 Copper(Aluminium)Conducter PVC Insulated and sheathed Power Cable

For laying indoor and outdoor tunnels, able to bear a centain traction installation, but unable to bear pulling force and pressure, single core cable can not be laid in the magnetic tube. Flame retardant, fire-resistant cable suitable for the places with higher requirements for fire protection.

 ZR-VV ZA-VV ZB-VV ZC-VV
 ZR-VLV ZA-VLV ZB-VLV ZC-VLV

 Copper(Aluminium)Conducter Flame Retardant PVC Insulated and sheathed Power Cable

 NH-VV NHZA-VV NHZB-VV
 NHZB-VV NHZC-VV

 Copper(Aluminium)Conducter Fire-resistant PVC Insulated and sheathed Power Cable

 VV22 VLV22

 Copper(Aluminium)Conducter PVC Insulated Steel Wire Armoured PVC Sheathed Power Cable

For laying direct in ground, able to bear a centain traction installation, pulling force and pressure, flame retardant, fire-resistant cable suitable for the place with higher requirements for fire protection.

 ZR-VV22 ZA-VV22 ZB-VV22 ZC-VV22
 ZR-VLV22 ZA-VLV22 ZB-VLV22 ZC-VLV22

 Copper(Aluminium)Conducter Flame Retardant PVC Insulated Steel Wire Armoured PVC Sheathed Power Cable

 NH-VV22 NHZA-VV22 NHZB-VV22
 NHZB-VV22 NHZC-VV22

 Copper(Aluminium)Conducter Fire-resistant PVC Insulated Steel Wire Armoured PVC Sheathed Power Cable

Production Range of Cable:

Type

No. of Cores

Nom. Cross-section of Conductor(mm²)

Copper Core

Aluminum Core

 

1 Core

1.5-630

2.5-630

 VV VLV ZR-VV ZA-VV ZB-VV ZC-VV ZR-VLV 

2 Cores

1.5-400

2.5-400

 ZA-VLV ZB-VLV ZC-VLV NH-VV NHZA-VV NHZB-VV

3 Cores

 NHZC-VV VV22 VLV22 ZR-VV22 ZA-VV22 ZB-VV22 

4 Cores

 ZC-VV22 ZR-VLV22 ZA-VLV22 ZB-VLV22 

5 Cores

 ZC-VLV22  NH-VV22 NHZA-VV22 NHZB-VV22

3+1 Cores

 NHZC-VV22 

3+2 Cores

 

4+1 Cores

Key words:

0.6/1KV 1.9/3.3KV PVC Insulated Armored Power Cable

Related Products

Product inquiry

Note: Please leave your contact information and our professionals will contact you as soon as possible!